DSO2C10 Digital Oscilloscope Dual Channel Economical Oscilloscope 100MHZ Bandwidth Handheld

RWF 600,000.00

Description

Cost-effective economy oscilloscope, 150MHz Bandwidth, 1GSa/s, 8M memory depth; with 1CH 25MHz waveform generator, support arbitrary waveform output; 14 kinds of trigger modes, standard with 5 kinds of serial protocol triggers and decodes; 32 kinds of auto measurements with statistics; 3-digit digital voltage meter and 6-digit hardware frequency indicator functions; 2 sets of DVM; Abundant SCPI remote command control. It is a useful commissioning instrument for various fields such as communication, aerospace, national defense, embedded systems, computers, research and education.

Specifications

modelDSO2D15DSO2D10DSO2C15DSO2C10
bandwidth150MHz100MHz150MHz100MHz
Number of oscilloscope channels2CH2CH2CH2CH
Built-in signal source1CH1CH – 
Oscilloscope index
Sampling rate range1GSa/s (single channel), 500MSa/s (dual channel)
Collection method
samplingSample data
Peak-to-peakDisplay high frequency and random glitches
average valueAverage waveform, times: 4, 8, 16, 32, 64, 128
High precisionUp to 12bit
enter
Input couplingDC, AC or ground (DC, AC, GND)
input resistance1MΩ±2% ‖20pF±3pF
Probe attenuation coefficient setting1X, 10X, 100X, 1000X
Voltage level300V CAT II
Maximum input voltage300VRMS (10X)
Horizontal system
Waveform interpolation(sin x)/x
Maximum record lengthMaximum 8M per channel
Maximum 4M for dual channels
Horizontal scale range2ns/div~100s/div 1, 2, 5 steps
Time base modeYT, XY, Roll
Zero offset±0.5 div×minimum time base gear
Sampling rate and delay time accuracy±50ppm
Clock drift≤±5 ppm/year
Incremental time measurement accuracySingle, “sampled” mode
(Full bandwidth)±(1 sampling interval+100ppm×reading+0.6ns)
>16 times above average
±(1 sampling interval+100ppm×reading+0.4ns)
Sampling interval = second/div÷200
Vertical system
modelDSO2D15DSO2D10DSO2C15DSO2C10
bandwidth150MHz100MHz150MHz100MHz
Rise time at BNC (typical)2.3ns3.5ns2.3ns3.5ns
Vertical resolution8-bit resolution, simultaneous sampling for each channel
Vertical sensitivity2mV/div to 10V/div
Offset range2mV/div to 20mV/div, ±100mV; 50mV/div to 200mV/div, ±1V;
500mV / div to 2V / cell, ± 10V; 5V / div to 10V / division, ± 50V
computationAdd, subtract, multiply, divide, FFT
FFTWindow: Rectangular, Hanning, Hamming, Brackman, Bartlett, flat top window
Bandwidth limit20MHz
Low frequency response (-3db)≤10Hz at BNC
Vertical gain accuracyIn the “sample” or “average” acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%;
In “Sampling” or “Average” acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%
DC offset accuracy±0.1 div±2 mV±1% offset value
Voltage measurement repeatability, average acquisition modeUnder the same settings and environmental conditions, the voltage increment between any two sets of average values ​​of more than 16 waveforms: ±(3%×reading+0.05 division)
Note: The bandwidth is reduced to 6MHz when using X1 probe
Trigger system
Trigger typeEdge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC
Trigger level range±5 divisions from the center of the screen
Trigger modeAutomatic, normal, single
LevelCH1~CH2±4 divisions from the center of the display
EXT0~3.3V
Range of relief8ns~10s
Trigger level accuracyCH1~CH20.2 divisions × volts/div within ±4 divisions from the center display
EXT±(6%+40mV of setting value)
Edge TriggerSlopeRising edge, falling edge, rising edge or falling edge
SourceCH1, CH2, EXT
Pulse width triggerpolarityPositive polarity, negative polarity
Condition (When)<, >, !=, =
SourceCH1~CH2,
Pulse width range8ns ~ 10s
Precision8ns
Video triggerSignal standardNTSC, PAL
SourceCH1~CH2
SynchronizeScan line, line number, odd field, even field, all field
Slope triggerSlopeRise and fall
Condition (When)<,>, !=, =
SourceCH1 ~ CH2
time limit8ns ~ 10s
Precision8ns
Timeout triggerSourceCH1~CH2,
polarityPositive polarity, negative polarity
time limit8ns ~ 10s
Precision8ns
Window triggerSourceCH1~CH2
Pattern triggerPattern0: low level; 1: high level; X: ignore; :rising; :falling; :rising or falling
Level (source)CH1~CH2
Interval triggerSlopeRise and fall
Condition (When)<,>, !=, =
SourceCH1~CH2,
time limit8ns ~ 10s
Precision8ns
Runt triggerpolarityPositive polarity, negative polarity
Condition (When)<,>, !=, =
SourceCH1~CH2
time limit8ns ~ 10s
Precision8ns
UART triggerCondition (When)Start, stop, data, parity, receive error
Source (RX/TX)CH1~CH2
Data FormatHex (hexadecimal)
Data length1 byte
Data bit width5 bit, 6 bit, 7 bit, 8 bit
Parity checkNone, odd, even
Idle levelHigh, low
Baud rate (optional)110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s
Baud rate (custom)300bit/s~334000bit/s
LIN triggerCondition (When)Interval field, sync field, ID field, sync error, identifier, ID and data
SourceCH1~CH2,
Data FormatHex (hexadecimal)
Baud rate (optional)110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200
Baud rate (custom)300bit/s~334000bit/s
CAN triggerCondition (When)Start bit, remote frame ID, data frame ID, frame ID, remote frame data, data frame data, error frame, all errors, response error, overload frame
SourceCH1~CH2
Data FormatHex (hexadecimal)
Baud rate (optional)10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000
Baud rate (custom)5kbit/s~1Mbit/s
SPI triggerSourceCH1~CH2,
Data FormatHex (hexadecimal)
Data bit width4, 8, 16, 24, 32
IIC triggerSource (SDA/SCL)CH1~CH2,
Data FormatHex (hexadecimal)
Data index0~7
Timing (condition)Start bits, stop bits, no answer, address, data, reboot
measuring
cursorVoltage difference between cursors△V
Time difference between cursors△T
The reciprocal of △T, in Hertz (1/△T)
Automatic measurementFrequency, period, average value, peak-to-peak value, root mean square, minimum value, maximum value, rise time, fall time, positive pulse width, negative pulse width, bottom value, top value, middle value, amplitude, overshoot , Preshoot, rising edge phase difference, falling edge phase difference, positive duty cycle, negative duty cycle, cycle average, cycle root mean square, falling edge overshoot, rising edge preshoot, BWIDTH, FRF, FFR, LRR , LRF, LFR, LFF
DVMdata sourceCH1, CH2
Measurement typeDC effective value
AC effective value
Direct current
frequency meterHardware 6-digit frequency counter
Signal source indicator
Number of channels1 channel
Sampling Rate200MSa/s
Vertical resolution12 bits
Highest frequency25 MHz
Standard waveformSine, square wave, pulse, triangle wave, sampling wave, exponential wave, noise
Arbitrary waveformArb1, Arb2, Arb3, Arb4
SineFrequency Range0.1Hz~25MHz
Square wave/pulseFrequency Range0.1Hz ~ 10MHz
Triangle waveFrequency Range0.1Hz~1MHz
Sample waveFrequency Range0.1Hz~1MHz
Exponential waveFrequency Range0.1Hz~5MHz
noise
Arbitrary Wave 1Frequency Range0.1 Hz to 10 MHz
Arbitrary Wave 2Frequency Range0.1 Hz to 10 MHz
Arbitrary Wave 3Frequency Range0.1 Hz to 10 MHz
Arbitrary Wave 4Frequency Range0.1 Hz to 10 MHz
Wave length8KSa
frequencyPrecision100 ppm (less than 10 kHz) 50 ppm (greater than 10 kHz)
Resolution0.1 Hz or 4 bits, whichever is greater
AmplitudeOutput range10mV~7Vp-p (high impedance)
5mV~3.5Vp-p(50Ω)
DC offsetrange±3.5 V, high resistance
±1.75 V, 50 Ω
Resolution100 μV or 3 bits, whichever is greater
Precision2% (1 kHz)
Output impedance50 Ω
General technical specifications
displayDisplay type7″ TFT LCD display diagonally
Display resolution800 (horizontal) * 480 (vertical) pixels
Display color16 million colors (24 bit true color)
Afterglow timeMinimum value, 1 s, 5 s, 10 s, 30S, unlimited
Display typePoint, vector
Display brightnessAdjustable
Grid typeOptional
Grid brightnessAdjustable
interfaceStandard interfaceUSB Host, USB Device
General technical specificationsProbe compensator output
Output voltage, typicalAbout 2Vpp input ≥1MΩ load
Frequency, typical1kHz
voltage100-120VAC RMS (±10%), 45Hz to 440Hz, CATⅡ
120-240VAC RMS (±10%), 45Hz to 66Hz, CATⅡ
Power consumptionLess than 30W
FuseT, 3.15A, 250V, 5x20mm
Operating temperature0~50 °C (32~122 °F)
storage temperature-40~+71 °C (-40~159.8 °F)
humidity≤+104℉(≤+40°C): ≤90% relative humidity
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
AltitudeWhen operating and not operating3,000m (10,000 feet)
Mechanical shockRandom vibration0.31g RMS from 50Hz to 500Hz ,
10 minutes per axis
When not operating2.46g RMS from 5Hz to 500Hz ,
10 minutes per axis
During operation50g, 11ms, half sine wave
Mechanical partOscilloscope size318 x 140 x 150mm (length x width x height)
weight2900g

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to top
× May I assist you?